Description
Features
Sends events to monitoring station receiver:
- Sends events to TRIKDIS software or hardware receivers that work with any monitoring software.
- Can send event messages to SIA DC-09 receivers.
- Connection supervision by polling to IP receiver every 30 seconds (or by user defined period).
- Backup channel that will be used if connection with the primary channel is lost.
- Events can be reported to CMS with SMS messages. SMS will be sent even if data connection stops working in the mobile operator network.
- When Protegus 2 service is enabled, events are first delivered to CMS, and only then are sent to app users.
Works with Protegus app:
- “Push” and special sound notifications informing about events.
- Remote system Arm/Disarm.
- Remote control of connected devices (lights, gates, ventilation systems, heating, sprinklers, etc.).
- Remote temperature monitoring (with iO or iO-WL expanders).
- Different user rights for administrator, installer and user.
- Users can also be informed about events with SMS messages and phone calls.
Notifies users about events:
- Sends SMS messages about events.
- “Push” and special sound event notifications using the Protegus 2
Remote system and output control:
- Using Protegus 2 app.
- Using contact (iButton) key reader.
- By calling the device’s phone number.
- Using SMS
- Using an automatic “..then” algorithm. E.g. when an input is enabled or the temperature exceeds a certain limit, an output will be turned on.
Supports these expanders:
- iO series wired or wireless expanders, which increase the number of inputs (IN) and outputs (OUT).
- GPS receiver (useful for protecting ATMs and vending machines).
- Fuel level sensor. For protecting fuel tanks or monitoring level.
- Backup power and charging of 12 V battery.
Inputs and outputs
- 1 input, 2 outputs and 3 I/O terminals that can be set either as input (IN) or controllable output (OUT) terminals.
- One wire data bus (1-Wire) for connecting temperature sensors (up to 8) and a contact (iButton) key reader.
- Number of inputs (IN) or outputs (OUT) can be increased to 12 using iO series wired or wireless expanders.
Simple installation:
- Default settings for use either as a control panel or as communicator.
- Settings can be saved to file and quickly written to other devices.
- Configuration either using an USB cable or remotely using TrikdisConfig
- Two types of access levels (accounts), for the installer and for the administrator.
Kelvin Mui –
Simple and Easy to Use